Industrial software, simulation and AI engineering US +1 510 396 3891 IN +91 70381 82558
Capabilities / Layer 2 / Gateways

Protocol gateways and custom software that connect what will not talk

We build protocol gateways for devices and systems that were never meant to meet, including devices whose vendor has gone. You get the gateway, its tests, the source and a guide your team can deploy from.

FIXED FIRST STEP
One connector
YOU SENDThe protocol or device documents and a capture or a test unit
YOU GETA working gateway service with tests, a deployment guide and the source
GATEWAYsite gateway / message map validate / map / normalise
IN386 msg/s
REJECTED TODAY3
QUEUE0
LAST MESSAGES
fleet/r2/stateok
line2/press/tempok
legacy/dev-07mapped
legacy/dev-11rejected
fleet/r1/orderok
Each message is checked against its model before it is passed on. A malformed one is logged, not forwarded.
01 / What it is for

Four jobs for OPC UA and MQTT integration.

01
Move devices off a dead platformWhen the vendor behind your devices has gone, we work out the protocol from what is left, stand up a replacement and move the devices over the air.
02
Connect a robot fleet to the plantFleet messages on VDA 5050 turned into tags, alarms and commands your SCADA understands.
03
Bring an old system onto OPC UAData from a system that predates OPC UA published as OPC UA, so a current SCADA can read it.
04
Clean up what arrivesUnits, field names and scales normalised on the way in, so every consumer reads the same data.
02 / How a build runs

Legacy system integration starts with a capture, not a datasheet.

STEP 1Capture the real trafficWe start from a capture or a test unit. A document says what a device should send. The capture says what it does.
STEP 2Model every messageEach message gets a model checked against the published schema or the captured traffic. A malformed message is rejected, not passed on.
STEP 3Build the translatorA small service maps messages to your tags, topics or tables and applies the alarm rules. Raise, acknowledge and clear are each tested.
STEP 4Test it end to endSimulated devices drive the whole path in a smoke test that runs from a fresh clone. The deployment guide is written alongside.
27 of 27end-to-end checks passing on a reference buildOur own fleet connector reference build: simulated robots and fleet manager, the broker, the translator and the screen, checked from end to end by its smoke test.
2 min 10 sfrom a fresh clone to every check passing on a clean machineOne run on a clean machine, timed from the clone to the last smoke check passing.
03 / Where it fits

Custom industrial software next to an off-the-shelf converter.

A DEVGIRI GATEWAY AN OFF-THE-SHELF PROTOCOL CONVERTER
MappingsWritten for your devices and your tag modelFixed to what the product supports
LogicValidation, state and alarm rules in code you can readMapping only
A device nobody supportsHandled from a captureWaits for the vendor
SourceYours, with the testsThe vendor's
Cost modelA fixed price per connector, source includedA box per site and the vendor's update cycle
Best whenThe device is odd, the vendor is gone or the logic mattersBoth ends speak a standard the box already supports
A robot fleet is one more connector. The same message models and tests carry VDA 5050 from a fleet manager to the plant.
See robotics and AMR integration
04 / Before you ask

What buyers want settled first.

What do you need from us to start?The protocol or device documents and a capture or a test unit. If there are no documents, a working unit and its firmware file are a start.
Which protocols do you handle?MQTT, OPC UA, VDA 5050 and REST. Beyond those, anything we can capture and read. We say before you buy whether a device is in reach.
How do we know it handles bad data?Malformed and out-of-range messages are part of the test set. Each one is rejected and logged, not passed on.
Can it run where there is no internet?Yes. The gateway runs on a small machine at the site and needs no outside service.
Who owns the gateway?You own the source, the tests and the guide for your connector. We keep generic libraries and license them to you with the build.

Send us one device.

A model number and a paragraph are enough. You get a scoping note within two working days, from the engineer who would build it.

Send us the brief